Use this option to synchronize Metadata settings between the Primary and Redundant sites.
Scope
The scope is limited to RMF-licensed devices selected by the Device Selection block and encompasses the features listed under the "Settings here correspond to" section in the picture below. The direction of synchronization depends on the direction setting. See Set Synchronization Direction. If no devices are selected in the Device Selection block, this option is disabled.
Enable
To enable and synchronize the Metadata settings, perform the following steps:
Click Metadata.
Note: For the Metadata block to be clickable, at least one device must be selected from the
Devices section. For more information, refer to Device Selection
Metadata Option
Enable the Overall Metadata Settings Sync to enable all the individual device metadata
settings. Enable/Disable different sub-settings as needed.
Metadata Settings Screen
Synchronize the Required Metadata Settings
Note: The highlighted section displays the associated metadata settings from the Site Navigation pane.
View Metadata Settings—Site Navigation Pane
To retain the settings, click the Check Mark button.
Check Mark Button
Click Save in the Milestone toolbar to save the changes.
Save Icon—Milestone Toolbar
Disable
To turn off the metadata settings synchronization, perform the following steps:
Click Metadata.
Metadata Option
To turn off the synchronization of the metadata settings, move the toggle button to display
red and click the Save icon.
Metadata Settings Disabled
Click Save in the Milestone toolbar to save the changes.
Save Icon—Milestone Toolbar
Step Result: The Metadata settings option is disabled.